| The PY non-contact displacement transducer measures the distance between its front face and a target made from a ferritic material. A ferritic material is one which is attracted by a magnet. This sensor is appropriate for high temperature, high pressure and high nuclear radiation position measurement applications. Many applications in turbines, in nuclear power stations and in research labs are appropriate for this sensor. There are two types of PY transducer, a single coil version (which must be used in pairs) and a double coil version which can be used alone. As the output of the PY is not linear, linearisation may be necessary depending on the application. Our 615 amplifier is designed for this. | |||||||||||||
| Single coil version. | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| The single coil displacement transducer version must be used in pairs for example one on each side of a rotation shaft. | |||||||||||||||
| |||||||||||||||
| Type | Maximum measurement gap | Operating temperature range | Maximum radiation dose | A | B | C | D | E | F | G | H | ||||
| PY102 | 0.1'' | -364°F to 428°F | 100M Rad | 0.47'' | 0.55'' | 0.47'' | 0.47'' | 0.33'' | 0.10'' | 0.49'' | 1.12'' | ||||
| PY106 | 0.1'' | -364°F to 1112°F | 100G Rad | 0.47'' | 0.55'' | 0.47'' | 0.47'' | 0.33'' | 0.10'' | 0.49'' | 1.12'' | ||||
| PY152 | 0.12'' | -364°F to 428°F | 100M Rad | 0.59'' | 0.71'' | 0.59'' | 0.51'' | 0.35'' | 0.20'' | 0.59'' | 1.50'' | ||||
| PY156 | 0.12'' | -364°F to 1112°F | 100G Rad | 0.59'' | 0.71'' | 0.59'' | 0.51'' | 0.35'' | 0.20'' | 0.59'' | 1.50'' | ||||
| PY252 | 0.24'' | -364°F to 428°F | 100M Rad | 0.98'' | 1.10'' | 0.98'' | 0.79'' | 0.35'' | 0.20'' | 0.59'' | 1.46'' | ||||
| PY656 | 0.24'' | -364°F to 1112°F | 100G Rad | 0.98'' | 1.10'' | 0.98'' | 0.79'' | 0.35'' | 0.20'' | 0.59'' | 1.46'' | ||||
| Double coil version. | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| The double coil transducer version can be used to measure the gap between a single PY and a suitable target. | |||||||||||||||
| |||||||||||||||
| Type | Maximum measurement gap | Operating temperature range | Maximum radiation dose | A | B | C | D | E | F | G | H | ||||
| PY102C | 0.1'' | -364°F to 428°F | 100M Rad | 0.47'' | 0.55'' | 0.47'' | 0.47'' | 0.37'' | 0.20'' | 0.71'' | 1.48'' | ||||
| PY106C | 0.1'' | -364°F to 1112°F | 100G Rad | 0.47'' | 0.55'' | 0.47'' | 0.47'' | 0.37'' | 0.20'' | 0.71'' | 1.48'' | ||||
| PY152C | 0.12'' | -364°F to 428°F | 100M Rad | 0.59'' | 0.71'' | 0.59'' | 0.51'' | 0.59'' | 0.39'' | 0.59'' | 1.93'' | ||||
| PY156C | 0.12'' | -364°F to 1112°F | 100G Rad | 0.59'' | 0.71'' | 0.59'' | 0.51'' | 0.59'' | 0.39'' | 0.59'' | 1.93'' | ||||
| PY252C | 0.24'' | -364°F to 428°F | 100M Rad | 0.98'' | 1.10'' | 0.98'' | 0.79'' | 0.59'' | 0.39'' | 0.59'' | 1.89'' | ||||
| PY256C | 0.24'' | -364°F to 1112°F | 100G Rad | 0.98'' | 1.10'' | 0.98'' | 0.79'' | 0.59'' | 0.39'' | 0.59'' | 1.89'' | ||||
| ||||||||||||
| ||||
|
||||
| Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment. | ||||
| RDP Electrosense 2216 Pottstown Pike Pottstown, PA 19465 USA Tel: 610-469-0850 Tel: 800-334-5838 Fax: 610-469-0852 Email: info@rdpe.com |
- |
|||