RDP Home Page Banner

Model RLW Industrial Weighing Compression Load Cell


Very high accuracy
Infinite resolution
Low cost
image of  Model  RLW Industrial Weighing Compression Load Cell
Our RLW load cell or force sensor is a device which converts load or force into an electrical signal.
This series of compression load cell is bolted down using the two mounting holes and the force applied to the threaded hole.
Care should be taken to ensure that the model RLW load sensor is not exposed to load or force in excess of its capability. The range of model RLW compression load cell selected should therefore be appropriate for the maximum force (including transient forces) that can be applied to it.
The RLW transducer is a strain gauge type transducer and has a mV output which may require an amplifier. For the RLW we can offer a variety of high quality, low noise and high precision strain gauge amplifiers.
Industrial Weighing Compression Load Cell
This series of compression load cell is bolted down using the two mounting holes and the force applied to the threaded hole.
dimensional drawing of  RLW Industrial Weighing Compression Load Cell
CD1=0.54''
CD2=0.20'' ±0.01''
CL1=0.9''
CL2=1.1''
Type Range A B C D E F G H M N P
RLW0010 10kgf (22lbs) 4.72'' 0.39'' 0.71'' 3.23'' 1.42'' 1.00'' M8 1.77'' 0.79'' 0.79'' 0.33''
RLW0025 25kgf (55lbs) 4.72'' 0.39'' 0.71'' 3.23'' 1.42'' 1.00'' M8 1.77'' 0.79'' 0.79'' 0.33''
RLW0050 50kgf (110lbs) 4.72'' 0.39'' 0.71'' 3.23'' 1.42'' 1.00'' M8 1.77'' 0.79'' 0.79'' 0.33''
RLW0100 100kgf (221lbs) 4.72'' 0.39'' 0.71'' 3.23'' 1.42'' 1.00'' M8 1.77'' 0.79'' 0.79'' 0.33''
RLW0250 250kgf (551lbs) 4.72'' 0.39'' 0.71'' 3.23'' 1.42'' 1.00'' M8 1.77'' 0.79'' 0.79'' 0.33''
RLW0500 500kgf (1.1klbs) 8.27'' 0.55'' 1.57'' 5.24'' 2.36'' 1.46'' M12 2.36'' 0.98'' 1.42'' 0.51''
RLW1000 1000kgf (2.2klbs) 8.27'' 0.55'' 1.57'' 5.24'' 2.36'' 1.46'' M12 2.36'' 0.98'' 1.42'' 0.51''
RLW1500 1500kgf (3.3klbs) 8.27'' 0.55'' 1.57'' 5.24'' 2.36'' 1.46'' M12 2.36'' 0.98'' 1.42'' 0.51''
Specification
Excitation/supply (acceptable) 0 to 15V
Excitation/supply (calibrated) 10V
Output 2mV/V ±10%
Zero balance 2% F.S.
Bridge resistance 350 Ω
Linearity error ±0.03% F.S.
Hysteresis ±0.03% F.S.
Repeatability ±0.03% F.S.
Resolution Infinite
Temperature coefficient (zero) ±0.002% F.S. /℉ (typical)
Temperature coefficient (span) ±0.002% F.S. /℉ (typical)
Operating temperature range -4℉ to 140℉
Compensated temperature range 14℉ to 104℉
Ingress protection (IP) 67
Over-range capacity 50%
Major construction material Steel
Electrical termination 9.8ft (integral cable)

Options and accessories