These transducers are for displacement / position measurement. They accurately measure the distance of suitable target from their front face. They use a capacitive measurement principle so there is not contact with the sensing element. These units also have built-in signal conditioning so they are powered from dc and give a dc output. A good target has a high relative permittivity and/or low resistivity. | ![]() |
| |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Type | Maximum measurement gap | L | W | Minimum target area | T | ||||
| B | H | ||||||||
| SG2.5 | 0.1'' | 2.38'' | 1.10'' | 0.39'' | 0.39'' | 0.20'' | |||
| SG5 | 0.2'' | 2.38'' | 1.10'' | 0.39'' | 0.39'' | 0.20'' | |||
| SG10 | 0.4'' | 2.87'' | 1.89'' | 0.59'' | 0.59'' | 0.24'' | |||
| SG20 | 0.8'' (Linearity specification valid over 90% Full Scale) | 2.91'' | 2.91'' | 1.97'' | - | 0.24'' | |||
| ||||||||||||||||||||||||
| Frequency response | ||
| Amplitude (% F.S.) | Electrical output bandwidth (Hz) | Phase shift (degrees) |
| 100 | 80 | 6 |
| 80 | 100 | 15 |
| 60 | 250 | 20 |
| 40 | 300 | 24 |
| 20 | 500 | 45 |
| 10 | 1000 | 90 |
| ||||
|
||||
| Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment. | ||||
| RDP Electrosense 2216 Pottstown Pike Pottstown, PA 19465 USA Tel: 610-469-0850 Tel: 800-334-5838 Fax: 610-469-0852 Email: info@rdpe.com |
- |
|||