How it Works - LVDT | ![]() | ||||||||||||
| These transducers are for displacement / position measurement. They make an accurate position measurement of the movement of the armature (the sliding part) relative to the body of the displacement transducer. This transducer uses the Linear Variable Differential Transformer (LVDT) principle which means that it is probably the most robust and reliable position sensor type available. The strength of the LVDT sensor's principle is that there is no electrical contact across the transducer position sensing element which for the user of the sensor means clean data, infinite resolution and a very long life. Our submersible displacement transducers are designed to make measurements whilst submerged in suitable liquids. Fluids which are non-magnetic can be allowed to flood the armature tube without affecting the operation of the transducer. The LVDTs are available as either unguided or spring return versions. LVDT transducers require external signal conditioning as detailed in the 'Electronics' section of this website. | |||||||||||||
| Unguided version.Connection details | ||||||||||
| On our unguided LVDTs the armature assembly is a separate component, to make a measurement the user must guide the armature inside the body without touching the sides. Unguided position measurement transducers are appropriate where external guidance is available and give truly non-contact operation | ||||||||||
| End (axial) exit cable. | |||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type | Range | Linearity error (% F.S.) | L | X | ID | Total weight | Armature weight | TF | Inward over-travel | Over-Travel | |||||||||||||||||||||||||
| Sensitivity (nom) | |||||||||||||||||||||||||||||||||||
| D5/40W | ±1mm | <±0,5/±0,25 | 46mm | 15,7mm | 2,30mm | 20g | 1,3g | 13mm | 2,0mm | 143mV/V | |||||||||||||||||||||||||
| D5/100W | ±2,5mm | <±0,5/±0,25 | 53mm | 19,5mm | 2,29mm | 22g | 1,4g | 14mm | 1,5mm | 375mV/V | |||||||||||||||||||||||||
| D5/200W | ±5mm | <±0,5/±0,25/±0,1 | 55mm | 26,3mm | 2,29mm | 24g | 1,8g | 19mm | 2,9mm | 320mV/V | |||||||||||||||||||||||||
| D5/300W | ±7,5mm | <±0,5/±0,25/±0,1 | 70mm | 30,0mm | 2,54mm | 26g | 1,8g | 19mm | 4,0mm | 435mV/V | |||||||||||||||||||||||||
| D5/400W | ±10mm | <±0,5/±0,25 | 74mm | 32,5mm | 2,54mm | 34g | 1,9g | 19mm | 3,9mm | 567mV/V | |||||||||||||||||||||||||
| MD5//500W | ±12,5mm | <±0,5/±0,25 | 90mm | 35,0mm | 2,54mm | 42g | 2,3g | 19mm | 3,9mm | 773mV/V | |||||||||||||||||||||||||
| Side (radial) exit cable.Connection details | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type | Range | Linearity error (% F.S.) | L | X | ID | Total weight | Armature weight | TF | Inward over-travel | Over-Travel | ||||||||||||||||||||||||||||||
| Sensitivity (nom) | ||||||||||||||||||||||||||||||||||||||||
| D5/40WRA | ±1mm | <±0,5/±0,25 | 48mm | 19,0mm | 2,30mm | 20g | 1,3g | 13mm | 2,0mm | 143mV/V | ||||||||||||||||||||||||||||||
| D5/100WRA | ±2,5mm | <±0,5/±0,25 | 53mm | 19,5mm | 2,29mm | 22g | 1,4g | 14mm | 1,5mm | 375mV/V | ||||||||||||||||||||||||||||||
| D5/200WRA | ±5mm | <±0,5/±0,25/±0,1 | 55mm | 26,3mm | 2,29mm | 24g | 1,8g | 18mm | 2,9mm | 320mV/V | ||||||||||||||||||||||||||||||
| D5/300WRA | ±7,5mm | <±0,5/±0,25/±0,1 | 70mm | 30,0mm | 2,54mm | 26g | 1,8g | 18mm | 4,0mm | 435mV/V | ||||||||||||||||||||||||||||||
| D5/400WRA | ±10mm | <±0,5/±0,25 | 74mm | 32,5mm | 2,54mm | 34g | 1,9g | 18mm | 3,9mm | 567mV/V | ||||||||||||||||||||||||||||||
| MD5/500WRA | ±12,5mm | <±0,5/±0,25 | 90mm | 35,0mm | 2,54mm | 42g | 2,3g | 18mm | 3,9mm | 773mV/V | ||||||||||||||||||||||||||||||
| Spring return version. | |||||||||
| Our spring displacement transducer has bearings to guide the armature inside the measurement sensor and a spring which pushes the armature to the fully out position. Spring return LVDTs are appropriate where it is not possible to connect the transducer armature to the moving component being measured. Spring return transducers should be cleared of air as trapped air may compress under pressure an cause errors. The mechanical frequency response of transducers may be reduced by fluid in the internal tubes. | |||||||||
| End (axial) exit cable.Connection details | |||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type | Range | Linearity error (% F.S.) | L | X | Total weight | Over-Travel | Sensitivity (nom) | ||||||||||||||||||||||||||||
| Inward over-travel | Outward over-travel | ||||||||||||||||||||||||||||||||||
| D5/40AW | ±1mm | <±0,5/±0,25 | 58mm | 11,5mm | 11g | 1,0mm | 1,5mm | 143mV/V | |||||||||||||||||||||||||||
| D5/100AW | ±2,5mm | <±0,5/±0,25 | 69mm | 12,5mm | 30g | 1,1mm | 1,1mm | 375mV/V | |||||||||||||||||||||||||||
| D5/200AW | ±5mm | <±0,5/±0,25/±0,1 | 76mm | 13,7mm | 34g | 1,4mm | 0,3mm | 320mV/V | |||||||||||||||||||||||||||
| D5/300AW | ±7,5mm | <±0,5/±0,25/±0,1 | 98mm | 15,3mm | 38g | 1,4mm | 1,3mm | 435mV/V | |||||||||||||||||||||||||||
| D5/400AW | ±10mm | <±0,5/±0,25 | 110mm | 19,0mm | 44g | 1,3mm | 1,3mm | 567mV/V | |||||||||||||||||||||||||||
| MD5/500AW | ±12,5mm | <±0,5/±0,25 | 132mm | 21,6mm | 52g | 1,9mm | 1,3mm | 773mV/V | |||||||||||||||||||||||||||
| Side (radial) exit cable.Connection details | ||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type | Range | Linearity error (% F.S.) | L | X | Total weight | Over-Travel | Sensitivity (nom) | |||||||||||||||||||||||||||||||||||
| Inward over-travel | Outward over-travel | |||||||||||||||||||||||||||||||||||||||||
| D5/40AWRA | ±1mm | <±0,5/±0,25 | 59mm | 11,5mm | 11g | 1,0mm | 1,5mm | 143mV/V | ||||||||||||||||||||||||||||||||||
| D5/100AWRA | ±2,5mm | <±0,5/±0,25 | 69mm | 12,5mm | 30g | 1,1mm | 1,1mm | 375mV/V | ||||||||||||||||||||||||||||||||||
| D5/200AWRA | ±5mm | <±0,5/±0,25/±0,1 | 76mm | 13,7mm | 34g | 1,4mm | 0,3mm | 320mV/V | ||||||||||||||||||||||||||||||||||
| D5/300AWRA | ±7,5mm | <±0,5/±0,25/±0,1 | 98mm | 15,3mm | 38g | 1,4mm | 1,3mm | 435mV/V | ||||||||||||||||||||||||||||||||||
| D5/400AWRA | ±10mm | <±0,5/±0,25 | 110mm | 19,0mm | 44g | 1,3mm | 1,3mm | 567mV/V | ||||||||||||||||||||||||||||||||||
| MD5/500AWRA | ±12,5mm | <±0,5/±0,25 | 132mm | 21,6mm | 52g | 1,9mm | 1,3mm | 773mV/V | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||
| Cable length | Standard cable | CSL (Cable sleeve length) = 2m, CL (Cable length) = 2m |
| Maximum cable sleeve length | 7m | |
| Option code TM0828 | CSL (Cable sleeve length) = 600mm, CL (Cable length) = 600mm to 1000m | |
| Option code TM0960 | CSL (Cable sleeve length) = 50mm, CL (Cable length) = 600mm to 1000m |
| ||||||||
|
||||
| Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment. | ||||
| Manufacturer RDP Electronics Ltd Grove Street, Heath Town Wolverhampton, West Midlands, WV10 0PY United Kingdom Tel: +44 1902 457512 Fax: +44 1902 452000 Email: sales@rdpe.com URL: www.rdpe.com |
Distributor Transducer Technology Unit 8, Canberra Industrial Park Derrick Coetzee Street Jet Park, 1459, South Africa Tel: +27 11 397 7733 Fax: +27 11 397 8909 Email: sales@transducers.co.za - |
|||