| Specification |
| V output | Supply voltage (dual) | ±12V to 40V dc, 30mA (typical) |
| Supply voltage (single, must be floating) | 24V to 40V dc, 30mA (typical) |
| Change in output for change in supply | 5mV/V |
| Output load | 10kOhms |
| Output ripple | 30mV (peak-to-peak typical) |
| Electrical output bandwidth | 200Hz |
| Output impedance | 2 Ohms |
| Operating temperature range | -50°C to 80°C* |
| 4-20mA output (>=±12,5mm) | Supply voltage | 12V to 36V dc |
| Max loop resistance | (Supply voltage-11) x 50 Ohms |
| Output ripple | 50uA (peak-to-peak) |
| Electrical output bandwidth | 200Hz |
| Operating temperature range | -10°C to 70°C* |
| Both outputs | Temperature coefficient (zero) | ±0,01% F.S. /°C (typical) |
| Temperature coefficient (span) | ±0,03% F.S. /°C (typical) |
| Maximum static pressure | 21MPa * |
| Electrical termination options * Transducer and cable option specifications should be compared and the worst figures used |
Standard cable - End exit connector with cable fitted |
 |  | | CL1 | = | 62mm | | Cable length | = | 5m | | Operating temperature range* | = | -25°C to 90°C | | Maximum static pressure* | = | 1000kPa | |
Option code 1 - End exit solder pins for customer to fit their own cable |
 |  | | CL1 | = | 21mm | | CL2 | = | 6,4mm | | CD1 | = | 12,7mm | | Operating temperature range* | = | -40°C to 125°C | |
Option code 2 - End exit fully sleeved integral cable |
 |  | | CL1 | = | 25mm | | CL2 | = | 51mm | | CD1 | = | 25mm | | CBD (Cable bend datum) | = | 184mm | | Cable length | = | 600mm to 7m | | Operating temperature range* | = | -40°C to 100°C | | Maximum static pressure* | = | 3MPa | |
Option code 3 - End exit part-sleeved integral cable |
 |  | | CL1 | = | 25mm | | CL2 | = | 51mm | | CD1 | = | 25mm | | CBD (Cable bend datum) | = | 70mm | | CSL | = | 600mm | | Cable length | = | 1000mm to 100m | | Operating temperature range* | = | -40°C to 90°C | | Maximum static pressure* | = | 2MPa | |
Option code 5 - End exit integral MI (mineral insulated) stainless steel cable |
 |  | | CL1 | = | 4mm | | CD1 | = | 3,0mm | | Cable length | = | 100mm to 70m | | Operating temperature range* | = | -40°C to 200°C | | Maximum static pressure* | = | 21MPa | | D5 | = | 11,7mm | |
Option code 6 - End exit connector with customer defined cable length fitted |
 |  | | CL1 | = | 64mm | | Cable length | = | 0mm to 1000m | | Operating temperature range* | = | -25°C to 125°C | | Maximum static pressure* | = | 800kPa | |
Standard cable 7 - Side exit connector with cable fitted |
 |  | | CBX | = | 25mm | | TR | = | M5x0,8, 11mm | | CL1 | = | 64mm | | Cable length | = | 5m | | Operating temperature range* | = | -25°C to 90°C | | Maximum static pressure* | = | 1000kPa | |
Standard cable 8 - Side exit fully sleeved integral cable~ |
 |  | | CBX | = | 25mm | | TR | = | M5x0,8, 11mm | | CL1 | = | 30mm | | CL2 | = | 55mm | | CD1 | = | 25mm | | CBD (Cable bend datum) | = | 184mm | | Cable length | = | 600mm to 7m | | Operating temperature range* | = | -40°C to 100°C | | Maximum static pressure* | = | 3MPa | |
Standard cable 9 - Side exit connector with customer defined cable length fitted |
 |  | | CBX | = | 25mm | | TR | = | M5x0,8, 11mm | | CL1 | = | 72mm | | Cable length | = | 0mm to 1000m | | Operating temperature range* | = | -25°C to 125°C | | Maximum static pressure* | = | 800kPa | |
Standard cable 10 - Side exit part-sleeved integral cable |
 |  | | CBX | = | 25mm | | TR | = | M5x0,8, 11mm | | CL1 | = | 30mm | | CL2 | = | 55mm | | CD1 | = | 25mm | | CBD (Cable bend datum) | = | 184mm | | CSL | = | 150mm | | Cable length | = | 600mm to 1000m | | Operating temperature range* | = | -40°C to 90°C | | Maximum static pressure* | = | 2MPa | |
Standard cable 11 - Side exit part-sleeved integral cable and conduit fitting |
 |  | | CBX | = | 25mm | | TR | = | M5x0,8, 11mm | | CL1 | = | 25mm | | CL2 | = | 50mm | | TC | = | 1/2''-14 NPT, 20mm | | CBD (Cable bend datum) | = | 184mm | | CSL | = | 150mm | | Cable length | = | 1000mm to 1000m | | Operating temperature range* | = | -40°C to 90°C | | Maximum static pressure* | = | 2MPa | |
|
| All dimensions and specifications are nominal. |
www.rdpe.com/za/dcw.htm |
20080110 |
|
| Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment. |
| |
Manufacturer RDP Electronics Ltd Grove Street, Heath Town Wolverhampton, West Midlands, WV10 0PY United Kingdom Tel: +44 1902 457512 Fax: +44 1902 452000 Email: sales@rdpe.com URL: www.rdpe.com
|
Distributor Transducer Technology Unit 8, Canberra Industrial Park Derrick Coetzee Street Jet Park, 1459, South Africa
Tel: +27 11 397 7733 Fax: +27 11 397 8909 Email: sales@transducers.co.za
- |