Model 47 Tension/Compression Load Cell (Universal Load Cell)

Very high accuracy
Stainless steel
High overload capacity
Infinite resolution
Fatigue rated



A load cell or force sensor is a device which converts load or force into an electrical signal.

A load cell should be mounted on a hard, flat surface. Tension/compression load cells measure the force applied to the centre threads of the load cell.

Care should be taken to ensure that the load sensor is not exposed to load or force in excess of its capability. The range of tension/compression load cell (universal load cell) selected should therefore be appropriate for the maximum force (including transient forces) that can be applied to it.

This series of transducer is a strain gauge type transducer and has a mV output which may require an amplifier. We can offer a variety of high quality, low noise and high precision strain gauge amplifiers.


How it Works - Strain Gauge Load Cell

A = 21mm
B = 25,4mm
H3 = 0,8mm
Type Range D1 H PCD Centre thread D2 H2 D3 Linearity error (% F.S.) Hysteresis Accuracy
SLC47/000250 250lbs (1,1kN) 105mm 63mm 88,9mm 5/8-18 UNF-3B 34mm 3mm 32mm ±0,02% F.S. ±0,02% F.S. ±0,02% F.S.
SLC47/000500 500lbs (2,2kN) 105mm 63mm 88,9mm 5/8-18 UNF-3B 34mm 3mm 32mm ±0,02% F.S. ±0,02% F.S. ±0,02% F.S.
SLC47/001000 1000lbs (4,4kN) 105mm 63mm 88,9mm 5/8-18 UNF-3B 34mm 3mm 32mm ±0,02% F.S. ±0,02% F.S. ±0,02% F.S.
SLC47/002500 2500lbs (11kN) 105mm 63mm 88,9mm 5/8-18 UNF-3B 34mm 3mm 32mm ±0,03% F.S. ±0,04% F.S. ±0,03% F.S.
SLC47/005000 5000lbs (22kN) 105mm 63mm 88,9mm 5/8-18 UNF-3B 34mm 3mm 32mm ±0,03% F.S. ±0,04% F.S. ±0,03% F.S.
SLC47/012500 12500lbs (56kN) 154mm 89mm 130,2mm 1-1/4-12 UNF-3B 67mm 3mm 57mm ±0,04% F.S. ±0,05% F.S. ±0,04% F.S.
SLC47/025000 25000lbs (111kN) 154mm 89mm 130,2mm 1-1/4-12 UNF-3B 67mm 3mm 57mm ±0,04% F.S. ±0,05% F.S. ±0,04% F.S.
SLC47/050000 50000lbs (222kN) 203mm 114mm 165,1mm 1-3/4-12 UNF-3B 96mm 6mm 76mm ±0,04% F.S. ±0,05% F.S. ±0,04% F.S.
SLC47/100000 100000lbs (445kN) 279mm 165mm 228,6mm 2-3/4-8 UNF-3B 122mm 13mm 114mm ±0,05% F.S. ±0,05% F.S. ±0,05% F.S.

Specification

Excitation/supply (acceptable)0 to 20Vdc Operating temperature range (maximum) 93°C
Excitation/supply (calibrated)10Vdc Compensated temperature range (minimum) -1°C
Output2mV/V Compensated temperature range (maximum) 54°C
Bridge resistance350 Ohms (SLC47/000250 = 700 Ohms) Deflection at full scale 0,064mm (Maximum)
Repeatability±0,01% F.S. Over-range capacity ±200% F.S.
Temperature coefficient (zero)±0,0014% F.S. /°C Major construction material Stainless steel
Temperature coefficient (span)±0,0014% rdg /°C Electrical termination Connector, mating part = PC06A-10-6S (or equivalent) (SAD-AA162)
Operating temperature range (minimum)-54°C    


All dimensions and specifications are nominal. www.rdpe.com/za/slc47.htm 20080110
Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment.
 
Manufacturer
RDP Electronics Ltd
Grove Street, Heath Town
Wolverhampton, West Midlands, WV10 0PY
United Kingdom
Tel: +44 1902 457512
Fax: +44 1902 452000
Email: sales@rdpe.com
URL: www.rdpe.com
Distributor
Transducer Technology
Unit 8, Canberra Industrial Park
Derrick Coetzee Street
Jet Park, 1459, South Africa

Tel: +27 11 397 7733
Fax: +27 11 397 8909
Email: sales@transducers.co.za

-