These transducers are for displacement / position measurement. They make an accurate position measurement of the movement of the armature (the sliding part) relative to the body of the displacement transducer.
This transducer uses the Linear Variable Differential Transformer (LVDT) principle which means that it is probably the most robust and reliable position sensor type available. The strength of the LVDT sensor's principle is that there is no electrical contact across the transducer position sensing element which for the user of the sensor means clean data, infinite resolution and a very long life.
The LVDTs are available as either unguided or spring return versions.
This transducer uses the Linear Variable Differential Transformer (LVDT) principle which means that it is probably the most robust and reliable position sensor type available. The strength of the LVDT sensor's principle is that there is no electrical contact across the transducer position sensing element which for the user of the sensor means clean data, infinite resolution and a very long life.
The LVDTs are available as either unguided or spring return versions.
Unguided version.
On our D5-D6 unguided LVDTs the armature assembly is a separate component, to make a measurement the user must guide the armature inside the body without touching the sides. Our D5-D6 unguided position measurement transducers are appropriate where external guidance is available and give truly non-contact operation
End (axial) exit cable.
D1=9.5mm (9.398mm to 9.498mm)
D3=2mm
TGF=M3x0.5
X=Centre of range
Side (radial) exit cable.
A=6mm (nominal)
D1=9.5mm (9.398mm to 9.498mm)
D3=2mm
TGF=M3x0.5
X=Centre of range
Spring return version.
Our D5-D6 spring displacement transducer has bearings to guide the armature inside the measurement sensor and a spring which pushes the armature to the fully out position. Our D5-D6 spring return LVDTs are appropriate where it is not possible to connect the transducer armature to the moving component being measured.
D6/00250A to D6/01000A
End (axial) exit cable.
End (axial) exit cable.
D1=8mm (7.965mm to 7.990mm)
X=Centre of range
D6/02500A to MD5/3000AG
End (axial) exit cable.
End (axial) exit cable.
D1=9.5mm (9.398mm to 9.498mm)
D3=4.75mm
X=Centre of range
D6/00250ARA to D6/01000ARA
Side (radial) exit cable.
Side (radial) exit cable.
A=6mm (nominal)
D1=8mm (7.965mm to 7.990mm)
X=Centre of range
D6/02500ARA to MD5/3000AGRA
Side (radial) exit cable.
Side (radial) exit cable.
A=6mm (nominal)
D1=9.5mm (9.398mm to 9.498mm)
D3=4.75mm
X=Centre of range
Specification
Connection details
Options and accessories
TM0315 Operating temperature range (maximum) = 200℃ | |
Mounting block for RDP transducers | |
E74 In-Line LVDT Amplifier | |
Amplifiers | |
Panel meter |