RDP Home Page Banner

Model 13 Compression Load Cell


Stainless steel
Infinite resolution
Miniature
image of Model  13  Compression Load Cell
Our SLC13 load cell or force sensor is a device which converts load or force into an electrical signal.
Care should be taken to ensure that the model SLC13 load sensor is not exposed to load or force in excess of its capability. The range of model SLC13 compression load cell selected should therefore be appropriate for the maximum force (including transient forces) that can be applied to it.
One particular feature of this transducer is its very small size
The SLC13 transducer is a strain gauge type transducer and has a mV output which may require an amplifier. For the SLC13 we can offer a variety of high quality, low noise and high precision strain gauge amplifiers.
Miniature compression load cell
The SLC13 load cell should be mounted on a hard, flat surface. Our SLC13 compression load cell measures the force applied to the load button.
dimensional drawing of  Model  13  Compression Load Cell
The cable may contain an in-line circuit board which cannot be removed
CL1=0.6m (nominal)
CL4=51mm (nominal)
Type D1 D2 H
250grams (2.5N) to 500grams (4.9N) 9.7mm 2.3mm 3.3mm
1000grams (9.8N) to 50lbs (222N) 9.7mm 2.3mm 3.3mm
100lbs (445N) to 250lbs (1.1kN) 12.7mm 3.0mm 3.8mm
500lbs (2.2kN) to 1000lbs (4.4kN) 19.1mm 6.4mm 6.4mm
Type Range Output Over-range capacity Total weight Deflection at full scale Gauge type Bridge resistance
SLC13G0250 250grams (2.5N) 15mV/V (nominal) 400% F.S. 1.1g 0.0015mm Semi 500 Ω
SLC13G0500 500grams (4.9N) 15mV/V (nominal) 400% F.S. 1.1g 0.0020mm Semi 500 Ω
SLC13G1000* 1000grams (9.8N) 1.5mV/V (nominal) 50% F.S. 1.1g 0.0013mm Foil 350 Ω
SLC13/0005 5lbs (22N) 2mV/V (nominal) 50% F.S. 1.1g 0.013mm Foil 350 Ω
SLC13/0010* 10lbs (44N) 2mV/V (nominal) 50% F.S. 1.1g 0.010mm Foil 350 Ω
SLC13/0025* 25lbs (111N) 2mV/V (nominal) 50% F.S. 1.1g 0.010mm Foil 350 Ω
SLC13/0050* 50lbs (222N) 2mV/V (nominal) 50% F.S. 1.1g 0.010mm Foil 350 Ω
SLC13/0100* 100lbs (445N) 2mV/V (nominal) 50% F.S. 3.1g 0.010mm Foil 350 Ω
SLC13/0250* 250lbs (1.1kN) 2mV/V (nominal) 50% F.S. 3.2g 0.013mm Foil 350 Ω
SLC13/0500* 500lbs (2.2kN) 2mV/V (nominal) 50% F.S. 10g 0.013mm Foil 350 Ω
SLC13/1000* 1000lbs (4.4kN) 2mV/V (nominal) 50% F.S. 10g 0.015mm Foil 350 Ω
Specification
Excitation/supply (calibrated) 5Vdc
Zero balance ±0.3% F.S.
Linearity error ±0.5% F.S.
Hysteresis ±0.5% F.S.
Repeatability ±0.1% F.S.
Temperature coefficient (zero) ±0.02% F.S. /℃
Temperature coefficient (span) ±0.04% rdg /℃
Operating temperature range -54℃ to 121℃
Compensated temperature range 16℃ to 71℃
Major construction material Stainless steel
Electrical termination 1.5m (integral cable)

Options and accessories