Model FP2000 Pressure Transducer

Very high accuracy
Internal amplifier
Stainless steel
Absolute pressure
Gauge pressure
Differential pressure
High resolution
This is a small selection of the available range
FPA/FPB/FPG/FPV Image Model DP wet/friendly in-line ports Model DP wet/wet in-line ports
FPA / FPB / FPG / FPV FDW FDD
       
The FP2000 series offers a modular selection which increases choice and reduces delivery time. We try to stock the various elements and simply weld them together to your requirements.

This unit is available in gauge, absolute, differential and barometric versions..
A gauge pressure transducer measures with respect to atmospheric pressure.
An absolute pressure transducer measures with respect to a vacuum.
A wet/wet differential pressure transducer measures the difference in the pressure applied to its two ports, both ports may contain liquid or gas.

This results in a wide range of mechanical and electrical options in a shorter lead-time.


Mechanical dimensions for body, electrical and port options
Electrical termination
Option code 6a
PT1H-10-6P (vented)
T = 7.6mm
Option code 6m
DIN43650 (vented)
T = 5.1mm
Option code 6n
DIN (vented)
T = 7.6mm
Option code 6q
integral cable (vented)
Cable length = 1.5m
T = 7.6mm
Option code 6r
integral cable with conduit fitting (vented)
Cable length = 1.5m
T = 7.6mm
Option 6a drawing Option 6m diagram Option 6m diagram Option 6q drawing Option 6q drawing
 
FPA, FPB, FPG, FPV FDW FDD
Drwaing of FPA Drawing of FDW Drawing of FDD
D = 29mm
L1= 74mm (<=5psi)
L1= 81mm (>=15psi)
D = 29mm
L1 = 97mm
L2 = 38mm
D = 29mm
L1 = 104mm
L2 = 23mm
Pressure port thread
Option code 5a
1/4-18 NPT female
H= 13mm (<=1000psi)
H= 25mm (>=1500psi)
Option code 5b
1/4-18 NPT male
H= 28mm (<=1000psi)
H= 33mm (>=1500psi)
Option code 5c
7/16-20 UNF female
H= 15mm (<=1000psi)
H= 25mm (>=1500psi)
Option code 5d
7/16-20 UNF male
H= 25mm (<=1000psi)
H= 33mm (>=1500psi)
Option code 5f
G1/4B female
H= 18mm (<=1000psi)
H= 25mm (>=1500psi)
Option code 5g
G1/4B male
H= 30mm (<=1000psi)
H= 30mm (>=1500psi)
Option 5a Drawing Option 5b drawing Option 5c drawing Option 5d drawing Option 5f drawing Option 5g drawing


Type FPG Gauge pressure A gauge pressure transducer measures with respect to atmospheric pressure
FPA Absolute pressure An absolute pressure transducer measures with respect to a vacuum
FPB Barometric pressure A barometric transducer measures low pressure levels with respect to a vacuum
FPV Vacuum pressure A vacuum transducer measures the depression below atmospheric pressure
FDD Differential pressure (Wet/dry) A wet/dry differential pressure transducer measures the difference in the pressure applied to its two ports, one of the ports can only contain a dry gas
FDW Differential pressure (Wet/wet) A wet/wet differential pressure transducer measures the difference in the pressure applied to its two ports, both ports may contain liquid or gas
Accuracy 1 0.1%
Thermal error band = 0.5%
0.1% F.S.   Output   2u 2e 2f 2n 2y
2 0.25%
Thermal error band = 1%
0.25% F.S.   Output   2u 2e 2f 2n 2y
Range UQ 16 to 32''Hg
(542 to 1084mBarA)
FPG FPA FPB FPV FDD FDW
UR 26 to 32''Hg
(880 to 1084mBarA)
UG 0 to 30''Hg
(0 to 1016mBarA)
WA 10''H2O (25mbar)
FPG FPA FPB FPV FDD FDW
AP 1psi (69mBar)
AT 5psi (345mBar)
FPG FPA FPB FPV FDD FDW
AV 10psi (689mBar)
FPG FPA FPB FPV FDD FDW
BJ 15psi (1bar)
FPG FPA FPB FPV FDD FDW
BM 30psi (2bar)
FPG FPA FPB FPV FDD FDW
BN 50psi (3bar)
BR 100psi (7bar)
CJ 150psi (10bar)
CN 250psi (17bar)
CR 500psi (34bar)
CT 750psi (52bar)
CV 1000psi (69bar)
DJ 1500psi (103bar)
FPG FPA FPB FPV FDD FDW
DM 2500psi (172bar)
DR 5000psi (345bar)
DT 7500psi (517bar)
DV 10000psi (689bar)
Output 2u mV/V
Supply voltage = 0 to 10V   Sensitivity (nom) =   FPG = 5 to 10mV/V FPA = 5 to 10mV/V FPB = 5 to 10mV/V
FPV = 5 to 10mV/V FDD = 5 to 10mV/V FDW = 5 to 10mV/V
2e 0 to 5V Supply voltage = 9 to 28V
2f 0 to 10V Supply voltage = 15 to 28V
2n 4-20mA (intrinsically safe ,<=5000psi) Supply voltage = 9 to 28V
2y 4-20mA Supply voltage = 9 to 28V
Pressure port thread 5a 1/4-18 NPT female  
5b 1/4-18 NPT male
5c 7/16-20 UNF female
5d 7/16-20 UNF male
5f G1/4B female
5g G1/4B male
Electrical termination 6a PT1H-10-6P (vented)  
6m DIN43650 (vented)  
6n DIN (vented)  
6q integral cable (vented) Cable length = 1.5m
6r integral cable with conduit fitting (vented) Cable length = 1.5m


Compensated temperature range
Type Range Compensated temperature range Compensated temperature range (Option code 1y)
Thermal error band = ±1%
FPG & FPA 10''H2O (25mbar) 4C to 43C 4C to 60C
1psi (69mBar) 4C to 43C 4C to 60C
5psi (345mBar),10psi (689mBar) & 15psi (1bar) 4C to 60C -7C to 77C
>15psi (1bar) 4C to 60C -18C to 82C
FPB 26 to 32''Hg
(880 to 1084mBarA)
16C to 43C 10C to 60C
16 to 32''Hg
(542 to 1084mBarA)
4C to 60C -1C to 77C
0 to 30''Hg
(0 to 1016mBarA)
4C to 43C -18C to 77C
FPV 10''H2O (25mbar) 4C to 43C 4C to 60C
1psi (69mBar) 4C to 43C 4C to 60C
5psi (345mBar),10psi (689mBar) & 15psi (1bar) 4C to 60C 4C to 77C
FDD & FDW 10''H2O (25mbar) & 5psi (345mBar) 4C to 43C 4C to 60C
>5psi (345mBar) 4C to 60C -17C to 77C


General Specification
  FPG/FPA FPV FPB FDW FDD
Over-range capacity <=1000psi 4X F.S. (3000psi maximum)
>=15000psi 4X F.S. (15000psi maximum)
<=1000psi 4X F.S. (3000psi maximum) <=1000psi 4X F.S. (3000psi maximum) Port 1 = 4X F.S. (3000psi maximum)
Port 2 = 4X F.S. (250psi maximum)
Port 1 = 4X F.S. (3000psi maximum)
Port 2 = 4X F.S. (250psi maximum)
Line pressure - - - 500 psi 500p psi
Port material Ha C276 & 316L ss Ha C276 & 316L ss Ha C276 & 316L ss Ha C276 & 316L ss Port 1 = Ha C276 & 316L ss
Port 2 = Dry air

Part number structure
Type Accuracy Range Output Pressure port thread Electrical termination Compensated temperature range (Option code 1y) Option code 3d CE Option code 14c
??? ? ?? 2? 5? 6? 0 0 9e
Output 2n = 9f
0


Example - FDW-1-CN-2y-5b-6a-1y-0-9e-0
Type Differential pressure (Wet/wet) FDW
Accuracy 0.1% 1
Range 250psi (17bar) CN
Output 4-20mA 2y
Pressure port thread 1/4-18 NPT male 5b
Electrical termination PT1H-10-6P (vented) 6a
Option code 1y Compensated temperature range (Option code 1y) 1y
Option code 3d - 0
Option code 9e/9f CE 9e
Option code 14c - 0

Options and accessories

Electronics
3d Remote buffered shunt cal
14c Side access to adjustment potentiometers  ( +/- 10% )


All dimensions and specifications are nominal. www.rdpe.com/uk/spt-fp2000.htm 20170119
Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment.
 
UK Head Office
RDP Electronics Ltd
Grove Street, Heath Town
Wolverhampton, West Midlands, WV10 0PY
United Kingdom
Tel: +44 1902 457512
Fax: +44 1902 452000
Email: sales@rdpe.com
URL: www.rdpe.com
Registered in England No. 1688591

-