LIN Extreme Environment Displacement Transducer

High cycle life
High radiation resistance
High temperature survival
Submersible
Stainless steel
Infinite resolution




   Data sheet (245kb)
These transducers are for displacement / position measurement. They make an accurate position measurement of the movement of the armature (the sliding part) relative to the body of the displacement transducer.

The LIN differential-inductance LVDTs are inductive (similar to an LVDT sensor) and because there is no contact across the sensor element it is very robust.

This sensor is appropriate for high temperature, high pressure and high nuclear radiation position measurement applications. Many applications in turbines, in nuclear power stations and in research labs are appropriate for this sensor.


The LVDTs are available as either unguided or spring return versions.

Unguided version..
On our unguided LVDTs the armature assembly is a separate component, to make a measurement the user must guide the armature inside the body without touching the sides. Unguided position measurement transducers are appropriate where external guidance is available and give truly non-contact operation
  ID= 0.177''
D1= 0.59''
D3= 0.138''
D4= 0.16''
TF= M3 x 0.5, 0.39''
Type Range Operating temperature range Maximum radiation dose L X (nom) Total weight Armature weight Over-Travel Linearity error (% F.S.)
Inward over-travel
LIN52 ±5mm (±0.2'') -364F to 428F 100M Rad 4.13'' 0.8'' 5.3oz 0.25oz 0.2'' <±0.5% F.S.
LIN56 ±5mm (±0.2'') -364F to 1112F 100G Rad 4.13'' 0.8'' 5.3oz 0.25oz 0.2'' <±1% F.S.
LIN152 ±15mm (±0.6'') -364F to 428F 100M Rad 7.17'' 1.6'' 7.1oz 0.46oz 0.6'' <±0.5% F.S.
LIN156 ±15mm (±0.6'') -364F to 1112F 100G Rad 7.17'' 1.6'' 7.1oz 0.46oz 0.6'' <±1% F.S.
LIN252 ±25mm (±1'') -364F to 428F 100M Rad 11.18'' 2.4'' 8.8oz 0.74oz 1.0'' <±0.5% F.S.
LIN256 ±25mm (±1'') -364F to 932F 100G Rad 11.18'' 2.4'' 8.8oz 0.74oz 1.0'' <±1% F.S.


Spring return version..
Our spring displacement transducer has bearings to guide the armature inside the measurement sensor and a spring which pushes the armature to the fully out position. Spring return LVDTs are appropriate where it is not possible to connect the transducer armature to the moving component being measured.
D1= 0.59''
TF= M3 x 0.5, 0.51''
SRD= 0.6''
Type Range Operating temperature range Maximum radiation dose L X (nom) Total weight Spring force (nom) Over-Travel Linearity error (% F.S.)
Spring force at X Spring rate Inward over-travel Outward over-travel
LIN52A ±5mm (±0.2'') -364F to 428F 100M Rad 4.69'' 2.2'' 6.0oz 1lbs 12oz/inch 0.3'' 0.92'' <±0.5% F.S.
LIN56A ±5mm (±0.2'') -364F to 662F 100G Rad 4.69'' 2.2'' 6.0oz 1lbs 12oz/inch 0.3'' 0.92'' <±1% F.S.
LIN152A ±15mm (±0.6'') -364F to 428F 100M Rad 7.76'' 3.9'' 7.8oz 2lbs 10oz/inch 1.0'' 0.80'' <±0.5% F.S.
LIN156A ±15mm (±0.6'') -364F to 662F 100G Rad 7.76'' 3.9'' 7.8oz 2lbs 10oz/inch 1.0'' 0.80'' <±1% F.S.
LIN252A ±25mm (±1'') -364F to 428F 100M Rad 11.77'' 3.7'' 9.5oz 2lbs 10oz/inch 0.4'' 0.79'' <±0.5% F.S.
LIN256A ±25mm (±1'') -364F to 662F 100G Rad 11.77'' 3.7'' 9.5oz 2lbs 10oz/inch 0.4'' 0.79'' <±1% F.S.



Specification

Excitation/supply (acceptable)0.5V to 5V rms, 2.4kHz to 9.6kHz (sinusoidal) Electrical termination 6.6ft (integral cable) Longer available to order.
Temperature coefficient (combined zero and span)±0.01% F.S. /F (typical) Maximum static pressure 2901psi (482F maximum)


Options and accessories

Electronics


All dimensions and specifications are nominal. www.rdpe.com/us/lin.htm 20170119