RDP Home Page Banner

Model D Through-Hole Compression Load Cell


Stainless steel
Infinite resolution
Miniature
image of Model  D Through-Hole Compression Load Cell
Our SLC-D load cell or force sensor is a device which converts load or force into an electrical signal.
This compression load cell measures the compressive force applied between the top and bottom of the load cell. It is particularly suited to applications where the load cell is bolted down.
Care should be taken to ensure that the model SLC-D load sensor is not exposed to load or force in excess of its capability. The range of model SLC-D compression load cell selected should therefore be appropriate for the maximum force (including transient forces) that can be applied to it.
One particular feature of this transducer is its very small size
The SLC-D transducer is a strain gauge type transducer and has a mV output which may require an amplifier. For the SLC-D we can offer a variety of high quality, low noise and high precision strain gauge amplifiers.
Compression load cell
Our SLC-D compression load cell measures the force applied to the load button.
dimensional drawing of  Model  D Through-Hole Compression Load Cell
Type Range OD ID H1 H2 H3 D1 D2
SLC-D-G0250 250grams (8.8oz) 0.5'' 0.10'' 0.15'' 0.02'' 0.01'' 0.2'' 0.45''
SLC-D-G0500 500grams (1.1lbs) 0.5'' 0.10'' 0.15'' 0.02'' 0.01'' 0.2'' 0.45''
SLC-D-G1000 1000grams (2.2lbs) 0.5'' 0.10'' 0.15'' 0.02'' 0.01'' 0.2'' 0.45''
SLC-D00005 5lbs 1.0'' 0.20'' 0.28'' 0.03'' 0.02'' 0.26'' 0.85''
SLC-D00010 10lbs 1.0'' 0.20'' 0.28'' 0.03'' 0.02'' 0.26'' 0.85''
SLC-D00025 25lbs 1.0'' 0.20'' 0.28'' 0.03'' 0.02'' 0.36'' 0.85''
SLC-D00050 50lbs 1.0'' 0.20'' 0.28'' 0.03'' 0.02'' 0.36'' 0.85''
SLC-D00100 100lbs 1.0'' 0.20'' 0.28'' 0.03'' 0.02'' 0.36'' 0.85''
BL913 Frame size A See table 1.5'' See table 0.5'' 0.05'' 0.03'' 0.5'' 1.21''
BL914 Frame size B See table 2.0'' See table 0.63'' 0.06'' 0.03'' 0.88'' 1.68''
BL915 Frame size C See table 3.0'' See table 1.0'' 0.08'' 0.03'' 1.70'' 2.46''
To order this product please specify range, frame size and hole letter
Hole letter P Q R S T V W Y Z
Actual hole dia. 3.25mm 4.90mm 6.76mm 9.93mm 13.51mm 16.66mm 19.84mm 26.21mm 32.54mm
Type Range Frame sizes available for each range (see table above for dimensions)
SLC-D00100 100lbs (445N) A A A A - - - - -
SLC-D00250 250lbs (1kN) A or B A or B A or B A or B B B - - -
SLC-D00500 500lbs (2kN) A or B A or B A or B A or B B B - - -
SLC-D01000 1000lbs (4kN) A or B A or B A or B B B B - - -
SLC-D02000 2000lbs (9kN) A, B or C A, B or C A, B or C B or C B or C B or C C C C
SLC-D03000 3000lbs (13kN) B or C B or C B or C B or C B or C C C C C
SLC-D05000 5000lbs (22kN) B or C B or C B or C B or C B or C C C C C
SLC-D07500 7500lbs (33kN) B or C B or C B or C B or C B or C C C C C
SLC-D10000 10000lbs (44kN) B or C B or C B or C B or C B or C C C C C
SLC-D15000 15000lbs (67kN) C C C C C C C C C
SLC-D20000 20000lbs (89kN) C C C C C C C C C
SLC-D30000 30000lbs (133kN) C C C C C C C C C
Specification
Bridge resistance < 5lbs = 500 Ω. ≥5lbs = 350 Ω.
Gauge type < 5lbs = Semi. ≥5lbs = Foil.
Transducer excitation < 5lbs = 5V. >= 5lbs = 10V.dc
Linearity error ±0.5% F.S.
Hysteresis ±0.5% F.S.
Repeatability ±0.1% F.S.
Resolution Infinite
Temperature coefficient (zero) < 5lbs = ±0.01% F.S. /℉. ≥5lbs + ±0.005% F.S. /℉.
Temperature coefficient (span) < 5lbs = ±0.02% rdg /℉. ≥5lbs + ±0.01% rdg /℉.
Operating temperature range -65℉ to 250℉
Compensated temperature range 60℉ to 160℉
Over-range capacity 50%
Major construction material Stainless steel
Electrical termination 5ft (Integral cable)

Options and accessories