Very high accuracy
Internal amplifier
Stainless steel
Absolute pressure
Gauge pressure
Differential pressure
High resolution
The FP2000 series offers a modular selection which increases choice and reduces delivery time. We try to stock the various elements and simply weld them together to your requirements.
This unit is available in gauge, absolute, differential and barometric versions..
The SPT-FP2000 gauge pressure transducer measures with respect to atmospheric pressure.
The SPT-FP2000 absolute pressure transducer measures with respect to a vacuum.
A wet/wet differential pressure transducer measures the difference in the pressure applied to its two ports, both ports may contain liquid or gas.
This results in a wide range of mechanical and electrical options and in a shorter lead-time.
This unit is available in gauge, absolute, differential and barometric versions..
The SPT-FP2000 gauge pressure transducer measures with respect to atmospheric pressure.
The SPT-FP2000 absolute pressure transducer measures with respect to a vacuum.
A wet/wet differential pressure transducer measures the difference in the pressure applied to its two ports, both ports may contain liquid or gas.
This results in a wide range of mechanical and electrical options and in a shorter lead-time.
Type
FPG | Gauge pressure | The SPT-FP2000 gauge pressure transducer measures with respect to atmospheric pressure |
---|---|---|
FPA | Absolute pressure | The SPT-FP2000 absolute pressure transducer measures with respect to a vacuum |
FPB | Barometric pressure | A barometric transducer measures low pressure levels with respect to a vacuum |
FPV | Vacuum pressure | A vacuum transducer measures the depression below atmospheric pressure |
FDD | Differential pressure (Wet/dry) | A wet/dry differential pressure transducer measures the difference in the pressure applied to its two ports, one of the ports can only contain a dry gas |
FDW | Differential pressure (Wet/wet) | A wet/wet differential pressure transducer measures the difference in the pressure applied to its two ports, both ports may contain liquid or gas |
FPA, FPB, FPG, FPV | FDW | FDD |
---|---|---|
D = 1.13'' L1= 2.9'' (≤5psi) L1= 3.2'' (≥15psi) |
D = 1.13'' L1 = 3.8'' L2 = 1.50'' |
D = 1.13'' L1 = 4.1'' L2 = 0.90'' |
Accuracy
1 | 0.1% Thermal error band = 0.5%. (Not available with output 2u (unamplified)) |
---|---|
2 | 0.25% Thermal error band = 1% |
Range
Output
2u | mV/V | Supply voltage = 0 to 10V. Sensitivity (nom) 2.5 to 10mV/V |
---|---|---|
2e | 0 to 5V | Supply voltage = 9 to 28V |
2f | 0 to 10V | Supply voltage = 15 to 28V |
2n | 4-20mA (Supply Current ,≤5000psi) | Supply voltage = 9 to 28V |
2y | 4-20mA | Supply voltage = 9 to 32V |
Pressure port thread
Cable Option 5a | Cable Option 5b | Cable Option 5c | Cable Option 5d | Cable Option 5f | Cable Option 5g |
---|---|---|---|---|---|
1/4-18 NPT female H= 0.5'' (≤1000psi) H= 1.0'' (≥1500psi) |
1/4-18 NPT male H= 1.1'' (≤1000psi) H= 1.3'' (≥1500psi) |
7/16-20 UNF female H= 0.6'' (≤1000psi) H= 1.0'' (≥1500psi) |
7/16-20 UNF male H= 1.0'' (≤1000psi) H= 1.3'' (≥1500psi) |
G1/4B female H= 0.7'' (≤1000psi) H= 1.0'' (≥1500psi) |
G1/4B male H= 1.2'' (≤1000psi) H= 1.2'' (≥1500psi) |
Electrical termination
Cable Option 6a | Cable Option 6m | Cable Option 6n | Cable Option 6q | Cable Option 6r |
---|---|---|---|---|
PT1H-10-6P (vented) T = 0.3'' |
DIN43650 (vented) T = 0.2'' |
DIN (vented) T = 0.3'' |
integral cable (vented) Cable length = 5ft T = 0.3'' |
integral cable with conduit fitting (vented) Cable length = 5ft T = 0.3'' |
Compensated temperature range
Type | Range | Compensated temperature range | Compensated temperature range (Cable Option 1y) Thermal error band = ±1% |
---|---|---|---|
FPG & FPA | 10''H2O (0.4psi) | 40℉ to 110℉ | 0℉ to 180℉ |
1psi | 40℉ to 110℉ | 0℉ to 180℉ | |
5psi,10psi & 15psi | 40℉ to 140℉ | 0℉ to 180℉ | |
>15psi | 40℉ to 140℉ | 0℉ to 180℉ | |
FPB | 26 to 32''Hg (12.8 to 15.7psiA) |
60℉ to 110℉ | 30℉ to 170℉ |
16 to 32''Hg (7.9 to 15.7psiA) |
40℉ to 140℉ | 30℉ to 170℉ | |
0 to 30''Hg (0.0 to 14.7psiA) |
40℉ to 110℉ | 30℉ to 170℉ | |
FPV | 10''H2O (0.4psi) | 40℉ to 110℉ | 0℉ to 170℉ |
1psi | 40℉ to 110℉ | 0℉ to 170℉ | |
5psi,10psi & 15psi | 40℉ to 140℉ | 0℉ to 170℉ | |
FDD & FDW | 10''H2O (0.4psi) & 5psi | 39℉ to 109℉ | -4℉ to 176℉ |
>5psi | 39℉ to 140℉ | -4℉ to 176℉ |
General specification
FPG/FPA | FPV | FPB | FDW | FDD | |
---|---|---|---|---|---|
Over-range capacity | ≤1000psi 4X F.S. (3000psi maximum) ≥15000psi 4X F.S. (15000psi maximum) |
≤1000psi 4X F.S. (3000psi maximum) | ≤1000psi 4X F.S. (3000psi maximum) | Port 1 = 4X F.S. (3000psi maximum) Port 2 = 4X F.S. (250psi maximum) |
Port 1 = 4X F.S. (3000psi maximum) Port 2 = 4X F.S. (250psi maximum) |
Line pressure | - | - | - | 500 psi | 500p psi |
Port material | Ha C276 & 316L ss | Ha C276 & 316L ss | Ha C276 & 316L ss | Ha C276 & 316L ss | Port 1 = Ha C276 & 316L ss Port 2 = Dry air |
Options and accessories
Amplifiers | |
Panel meter | |
3d Remote buffered shunt cal | |
14c Side access to adjustment potentiometers ( +/- 10% ) |
Example - FDW-1-CN-2y-5b-6a-1y-0-0 | ||
---|---|---|
Type | Differential pressure (Wet/wet) | FDW |
Accuracy | 0.1% | 1 |
Range | 250psi | CN |
Output | 4-20mA | 2y |
Pressure port thread | 1/4-18 NPT male | 5b |
Electrical termination | PT1H-10-6P (vented) | 6a |
Cable Option 1y | Compensated temperature range (Cable Option 1y) | 1y |
Cable Option 3d | - | 0 |
Cable Option 14c | - | 0 |